Posted in | Position Sensors

Sensor Measurement System - FBG-SCAN 700/800

The FBG-Scan 700 and 800 from FBGS are dynamic, high precision measurement systems for Fiber Bragg Grating (FBG) sensors. The system can measure up to 40 FBG sensors using two input channels. Both input channels are simultaneously monitored using an optical coupler at a scan rate up to 2000 Hz.

The FBG-Scan 700 and 800 are supplied along with ‘Illumisense’ V2.2 measurement software.

Parameter FBG-Scan
700 800
Optical
Wavelength range 1525-1565 nm 1510-1590 nm
Minimum wavelength spacing1 0.4 nm 0.8 nm
Number of optical lines2 2 (same optical line: 1x2 optical coupler)
Wavelength precision ± 1 pm
Absolute wavelength accuracy (EOL)3 ± 30 pm ± 40 pm
Dynamic range 30 dB with user selectable control
Scan and report rate 2000 Hz
Optical connector FC/APC
Laser class (IEC 60825-1) 1
Electrical
Communication USB 2.0
Trigger signal TTL signal (3.3 V), SMA connector
Power supply 5 VDC
Environmental
Operating temperature 10 °C to 40 °C
Operating humidity 0% to 80%, non-condensing
Storage temperature -10 °C to 60 °C
Storage humidity 0% to 95%, non-condensing
Mechanical
Dimensions (W x D x H) 260 mm x 230 mm x 60 mm

Note:
1 Based on FRG with FWHM of 100 pm.
2 Extendable with 1x8 or 1x16 optical switch supporting 1 Hz measurements
3 Higher absolute wavelength accuracies available on ret.