Assess the Photobiological Safety of Lamps and Lamp Systems – IDR300-PSL

Lamp and luminaire manufacturers and test and certification companies can now measure photobiological safety of lamps and lamp systems easier, faster, and with higher accuracy than ever before.

Photobiological safety testing to follow global standards needs a measurement capability spanning the 200-3000 nm spectral wide range in consideration to six hazards to the eye and skin. The IDR300-PSL spectroradiometer from Bentham facilitates the necessary series of spectral radiance and spectral irradiance measurements, while ensuring total compliance with the recommended measurement instrumentation. The total hardware automation and full measurement guidance, calculation, and report generation enable the IDR300-PSL to be at the core of photobiological safety testing in accreditation and the light source manufacturer's laboratories worldover.

Core Benefits

  • Assess all product types, from UV through to IR
  • Includes complete measurement guidance, calculation and report generation
  • Completely compliant to instrumentation recommendation of international standards
  • Quality of measurements assured through NMI calibration standards traceable to PTB

Features

  • Motorized slits to modify instrument bandwidth throughout scan range
  • Quartz halogen, integrating sphere-based radiance standard, delivered with calibration traceable to PTB, Germany
  • Quartz halogen and deuterium irradiance standards, provided with calibration traceable to PTB, Germany
  • 5 and 11 mrad FOVs. Connected to IDR300 with 1 m long quartz fiber bundle
  • Photometric detector with virtual luxmeter operation for establishing illuminance (500 lx, dthr)
  • Beam profiler employed to establish (apparent) source size and location
  • Irradiance: Precision transmission diffuser linked to IDR300 with 1 m long quartz fiber bundle
  • Radiance: Direct view telescope allowing measurement from 200 mm to 10 m in key 1.7, Double monochromator-based spectroradiometer (200-3000 nm)
  • Benwin+ Windows spectroradiometer control
  • PSL Wizard measurement guidance, calculation, and report generation application

Applications

Accurate photobiological safety evaluation to:

  • IEC 62471-5:2015, Photobiological safety of lamps and lamp systems - Part 5: Image projectors
  • EN 62471:2008, Photobiological safety of lamps and lamp systems
  • IEC 62471:2006, Photobiological safety of lamps and lamp systems
  • JIS C 7550:2011, Photobiological safety of lamps and lamp systems
  • EU Low Voltage Directive, 2014/35/EU
  • IEC TR 62471-2:2009, Photobiological safety of lamps and lamp systems - Part 2
  • EN 62471-5:2015, Photobiological safety of lamps and lamp systems - Part 5: Image projectors

Reported Parameters

  • Labeling requirements
  • Spectral irradiance
  • (Apparent) Source size and location
  • Risk group classification
  • Threshold distance, dthr
  • Threshold illuminance, Ethr
  • Spatially averaged spectral radiance