The Lion Precision ECL202 eddy-current displacement sensor provides highest precision with a digital core and push-button controls.
Key Features:
The product features of the ECL202 eddy-current displacement sensor are:
-
Linearity: ±0.2%
-
Resolution (typical):
(Dependent on Probe and Range)
-
ECL202 Non-ferrous: 0.006% RMS
-
ECL202 Ferrous: 0.008% RMS
-
ECL202e: 0.2 µm RMS or higher
-
"Fine" ranges available for higher resolution
-
0-10 VDC output
-
15 kHz bandwidth
-
Push-button switch threshold (setpoint)
-
Push-button offset
-
Remote offset and threshold activation
-
Range indicating LEDs
-
Probes can be ordered as vacuum compatible
-
User-selectable bandwidth/resolution 100 Hz, 1 kHz, 10 kHz, 15 kHz
-
CE Compliant.
Specifications
The specifications of the ECL202 eddy-current displacement sensor are:
|
|
|
Resolution:
RMS, Typical
Dependent on probe and range. |
ECL202 |
0.006% (Non-ferrous)
0.008% (Ferrous) |
ECL202e |
Greater of 0.2 µm or
0.006% (Non-ferrous)
0.008% (Ferrous) |
Linearity |
±0.2% of Range |
Error Band |
±0.4% of Range |
Bandwidth |
Selectable: 100 Hz, 1 kHz, 10 kHz, 15 kHz |
Driver Temperature Drift
(15°C-50°C)
Typical. See Probe/Range chart for details. |
|
Driver Temperature Drift
(15°C-50°C)
Typical. See Probe/Range chart for details. |
±0.01% F.S./°C |
Probe Temperature Drift
(15°C-65°C, except where noted)
Typical. See Probe/Range chart for details. |
±0.01% F.S./°C |
Analog Output |
0-10 VDC, 0 Ù, 15 mA |
Switched Output |
30 VAC/60 VDC/100 mA |
Input Power |
12-24 VDC
1.9 W |
Driver Operating Environment |
4°C-50°C
IP40 |
Probe Operating Environment
Standard Probes come with PUR (Polyurethane) jacketed cables. High Temperature Probes have FEP jackets.
Other temperature ranges may be possible.
Standard Probes: IP67
High Temperature Probes: IP63 |
U3 Probe |
Standard Probe (PUR Cable):
-25°C to +125°C
(Available with optional FEP cable)
High Temperature Version Not Available |
U5-18 Probes |
Standard Probes:
-25°C to +125°C
High Temperature Probes:
-25°C to +200°C |
U25-50 Probes |
Standard Probes:
-25°C to +125°C
High Temperature Probes:
-25°C to +175°C |