CO2Meter's Multi-Gas Safety System Tablet is engineered to monitor carbon dioxide levels and detect leaks across multiple locations from a single central display unit. The system is a true "plug-and-play" system tailored to specific applications and requirements. This device can also be seamlessly integrated with CO2Meter's Multi-Gas Safety System.
Users can work with a sales specialist to create a custom system for their desired application, or choose specific system components.
Image Credit: CO2Meter
System Components
- Tablet for Multi-Gas Safety System (CM-7005)
- CO2 Sensor for Multi Gas Safety System (CM-7003)
- Oxygen Sensor for Multi Gas Safety System (CM-7103)
- Relay for Multiple Gas Safety System (CM-7002)
- Horn Strobe for Multi-Gas Safety System (CM-7004)
- The CM-7004-OUT Multi Gas Safety Exterior Horn Strobe
- Tablet with Multiple Gas Safety Mini Display System (CM-7006)
- Tower Strobe (CM-1026-5)
- SV-1029, a 3/8" solenoid shut-off valve
- SV-1030, a 1/2-inch solenoid shut-off valve
Features
- Add any number of additional CO2 sensors as the business grows
- All alarm and notification settings are fully customizable to suit specific needs
- Meets NFPA, IFC, and NBIC requirements, as well as OSHA and NIOSH TWA standards
- Complies with all local municipality inspection codes and requirements
Specifications
- Alarms: 5,000 TWA, 5,000 ppm, 1.5%, and 3% (default)
- CO2 Measurement: NDIR (Non-Dispersive Infrared
- Calibration: Zero with Nitrogen or Factory Calibration
- Connections: Input / Output / Strobe - CAT5 8-pin connector
- Custom Alarms: 1%, 2%, 2.5%, 3.5%, 4%
- Measurement interval: 2 seconds (0.5 Hz)
- Measurement Range: 0-5% (0-50,000 ppm)
- Operating Temperature: 32-122 °F (0-50 °C)
- Sensor Life Expectancy: > 15 years
Electrical
- Wall Power Plug: 110-220 VAC 50/60 Hz to 48 VDC Power Adapter
- Power Input: 48-58 VDC
- Power Consumption: 30 W
- Horn Strobe: 90-120 dB 3 KHz, 110 CD
- 48-58 VDC hard-wired power option
- It can be connected to a UPS for Battery Backup
- The maximum distance any sensor or horn/strobe can be from the tablet is 250 ft. without additional POE devices
Connectivity
- With proper setup, the CM-7005 tablet can effectively control an array of CO2, O2, and remote relay components.
- For system sizes exceeding the specified limits—more than 5 CM-7004 Horn Strobes per port, over 12 CM-7004 Horn Strobes per tablet, or a range exceeding 250 ft.—the use of our Power Over Ethernet Adapters is necessary due to power requirements.
- Contact CO2Meter directly to configure large installations
Software
Required Firmware Update - Released June 2023
Users are encouraged to download the CM-7000 v2.3.15's most recent firmware.
The following updates are necessary for all CO2 Multi-Sensor Systems to work at their best:
- Get the detailed upgrade instructions.
- Get the most recent firmware for the CM-7000.
Accessories
The Multi Gas Safety System starts with the CM-7005 tablet.
- Calibration Gas: Due to MDOT regulations, calibration gases must be shipped from a certified gas supplier.
- Horn Strobe CM-7004: Audible and visual strobe alarm used for interior placements.
- Horn Strobe CM-7004-OUT: Audible and visual strobe alarm for exterior placements.
- Multi-Gas Safety System CO2 Sensor (CM-7003): Provides real-time CO2 readings for multiple sensors that are controlled by the CM-7005 CO2 multi-sensor safety system tablet.
- Multi-Gas Safety System Oxygen Sensor (CM-7103): Provides real-time O2 readings for multiple sensors that are controlled by the CM-7005 CO2 multi-sensor safety system tablet.
- Multi-Gas Safety System Relay CM-7002: Triggers third-party devices like an exhaust fan, building management system, fire panel or remotely notify security of a high CO2 alarm. Includes CBL-7002 below.
- Multi-Gas Mini Display System Tablet CM-7006: Remote display that monitors all or a group of CO2 sensors.
- Relay Cable CBL-7002: Enables easy connectivity between the Remote Relay CM-7002, Strobe Tower CM-1026-5 or any external device that can be triggered by a relay.
- Strobe Tower CM-1026-5: Provides a flashing indicator and audible alarm. Changes colors as the alarm level changes.
- Solenoid Safety Shut-Off Valve SV-1029: 3/8 inch connector on electronic solenoid enables remote shut off during gas leak. Plug it into the remote relay CM-7002 or main tablet relay.
- Solenoid Safety Shut-Off Valve SV-1030: 1/2 inch connector on electronic solenoid enables remote shut off during gas leak. Plug it into the remote relay CM-7002 or main tablet relay.