Emerson’s New Flow Measurement Solution Improves Data Center Reliability, Efficiency, and Uptime

Global automation leader Emerson today announced the new Rosemount™ 8795 Magnetic Flow Sensor, purpose-built for data center hydronic cooling applications. This industrial-grade flow sensor provides accurate, repeatable flow measurements for high reliability and uptime in mission-critical data center applications. Designed for data center environments, the flow sensor addresses common specification needs to simplify selection, installation, and commissioning.

Emerson's Rosemount™ 8795 Magnetic Flow Sensor with Rosemount 9732 Magnetic Flow Transmitter. Image Credit: Emerson Electric Co.

"As data centers expand to support growing digital infrastructure demands, the Rosemount 8795 applies decades of Emerson flow measurement expertise to help operators improve reliability, simplify deployment, and maximize cooling system performance in mission-critical applications," said Bob Halgren, vice president magnetic and vortex flow products with Emerson's measurement instrumentation business.

The flow sensor can host Emerson's proprietary software designed for short-run installations, enabling accurate flow measurement even when straight pipe requirements cannot be met, as is often the case in space-constrained data center environments. This feature provides 0.5% accuracy at zero diameters (0D) of pipe runs based on the upstream disturbance and distance from the electrodes, and it is implemented during setup when the sensor is paired with compatible Rosemount Magnetic Flow Transmitters. This is an industry first as other mag meters require either a specialty designed sensor with multiple electrodes or a reduced bore to provide this benefit.

For installations with longer upstream and downstream straight pipe runs of 5U/2D or more, the flow sensor can be paired with any compatible Rosemount transmitters to provide flow measurement with 0.2%  2 mm/s accuracy for reliable monitoring and control of critical cooling loops. With all compatible Rosemount transmitters, the built-in diagnostics and verification capabilities empower data center operators and integrators to reduce commissioning risk, while maintaining confidence in ongoing system performance.

Optimized for chilled water and water glycol cooling loops, the sensor provides consistent performance across common data center line sizes of 2–18 inches. Proven reliability and 0.1% repeatability ensures highly reliable and accurate data sent to building management systems (BMS) and data center infrastructure management (DCIM) for water, cooling, and power usage effectiveness (WUE, CUE, PUE) calculations. Its polytetrafluoroethylene (PTFE) liner and stainless-steel electrodes were selected specifically for these types of thermal management applications in primary cooling loops, ensuring dependable operation in closed-loop cooling systems.

The industrial-grade flow sensor is designed to meet common BMS cooling specifications, while also being flexible for various situational needs. Functionality includes no moving parts, 5µS/cm minimum conductivity, dual 4-20mA plus Modbus output, universal power for AC or DC usage, flexibility for integrally or remotely mounted transmitters, and Short Run Installation software. These functions enable standardization around a single solution for all hydronic needs at a Data Center site. Emerson's :censored:6:cdd6bbaa89: supply chain shortens lead times at the scale required by data centers.

The Rosemount 8795 brings enhanced software capabilities and simplified ordering to Emerson's existing magnetic flow meter portfolio, strengthening Emerson's instrumentation offering for data center customers.

Citations

Please use one of the following formats to cite this article in your essay, paper or report:

  • APA

    Emerson Electric Co.. (2026, October 09). Emerson’s New Flow Measurement Solution Improves Data Center Reliability, Efficiency, and Uptime. AZoSensors. Retrieved on October 09, 2026 from https://www.azosensors.com/news.aspx?newsID=16979.

  • MLA

    Emerson Electric Co.. "Emerson’s New Flow Measurement Solution Improves Data Center Reliability, Efficiency, and Uptime". AZoSensors. 09 October 2026. <https://www.azosensors.com/news.aspx?newsID=16979>.

  • Chicago

    Emerson Electric Co.. "Emerson’s New Flow Measurement Solution Improves Data Center Reliability, Efficiency, and Uptime". AZoSensors. https://www.azosensors.com/news.aspx?newsID=16979. (accessed October 09, 2026).

  • Harvard

    Emerson Electric Co.. 2026. Emerson’s New Flow Measurement Solution Improves Data Center Reliability, Efficiency, and Uptime. AZoSensors, viewed 09 October 2026, https://www.azosensors.com/news.aspx?newsID=16979.

Tell Us What You Think

Do you have a review, update or anything you would like to add to this news story?

Leave your feedback
Your comment type
Submit

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.